Stair Calculator
This stair calculator lays out one straight flight from total floor-to-floor rise, a target maximum riser and a chosen tread going. It rounds the riser count upward, then calculates equal risers, horizontal run and the geometric stringer length in metric or imperial units.
By Dr. Hassan Khames EliwaLast updated
Result
- Actual riser
- 176.47 mm
- Treads
- 16
- Total run
- 4.48 m
- Stringer length
- 5.39 m
How it works
Establish the finished levels first
Measure vertically between the finished lower and upper walking surfaces. A slab-to-slab measurement can be misleading when the two levels receive different floor build-ups. Enter metres for total rise in metric mode, with millimetres for risers and treads. Imperial mode uses feet for total rise and inches for the smaller dimensions. Switching the selector changes interpretation; it does not convert the numbers already entered.
Equal rises, one fewer tread
Riser count is the ceiling of total rise divided by the target maximum rise. Actual riser height is total rise divided by that whole count. This deliberately treats the target as a ceiling, not a preferred value that can be exceeded by rounding to the nearest integer. A flight terminating at an upper landing has one fewer separate tread than risers. Run therefore equals tread count multiplied by tread going, after conversion into the total-rise unit.
A geometric length, not a cutting schedule
The reported stringer length is the hypotenuse formed by total rise and total run. It does not include end bearings, connection details, nosings or material needed beyond the theoretical slope. Landings, turns, winders, alternating treads and changes in flight width are outside this model. The chosen tread is horizontal going, not the full board depth including a nosing. Results are a layout starting point, never a statement of code compliance.
Test the flight against the space around it
Set the calculated run onto the plan from a clearly identified starting riser. Then check the upper opening and the section through the stair: fitting the footprint between two walls does not establish adequate headroom. The upper landing is outside the tread run reported here, so reserve its space separately. If a landing or doorway forces a different arrangement, revisit the flight layout before choosing material. You may need several flights rather than a steeper version of the same straight stair. Keep the finished-level survey and the unrounded riser division together for the person setting out the work.
Worked example
Scenario 1: a metric straight flight
For a 3 m finished rise, 180 mm maximum target riser and 280 mm tread going, 3,000 ÷ 180 is 16.6667. Round upward to 17 risers. Each actual riser is 176.47 mm. There are 16 treads, giving 16 × 280 = 4,480 mm, or 4.48 m, of run. The theoretical stringer is 5.39 m. Keep unrounded dimensions in the setting-out schedule; seventeen independently rounded rises should not accumulate a closure error.
Scenario 2: an imperial layout
A 10 ft rise is 120 inches. With a 7.5 in target riser and 10 in tread going, the flight needs 16 risers of exactly 7.50 in and 15 treads. Its run is 12.50 ft and its theoretical stringer is 16.01 ft. These are geometric results only. The first and last risers still need checking against the actual floor finishes and support arrangement.
Expert tips
Common mistakes
- Counting the upper landing as another tread overstates this straight-flight run. That adds one going and changes the predicted footprint.
- Your target maximum is a layout input, not a legal limit that applies everywhere. Local rules may also limit total flight rise, headroom, width and riser variation.
- Stock cut to the theoretical slope length alone may be too short for the finished stringer. Bearings, fastening zones, saw cuts and fabrication details require separate allowances.
Frequently asked questions
Does this check building regulations?
No. It checks arithmetic and basic positive dimensions only. Confirm the adopted local code, occupancy requirements and approval conditions with the responsible designer before construction.
Why round the riser count upward?
An upward count keeps the calculated equal rise at or below the entered target. Rounding downward could create risers taller than the limit you intended to use.
Can I calculate an L-shaped stair?
Calculate each straight flight separately once the landing levels and dimensions are fixed. This tool does not allocate rise between flights or size the intermediate landing.
Is tread going the same as board depth?
Not necessarily. Going is the horizontal spacing between successive nosing lines. Board depth may include overlap or a projecting nosing, which should not be counted twice.
Why is there a minimum of two risers?
The model describes a flight with separate treads between finished levels. A single threshold step needs a different detail and is rejected rather than producing a zero-run flight.
Related calculators
Related guides
Construction & ProjectThree-point estimating: when PERT beats a single guessA practical guide to three-point duration estimates, weighted averages and the limits of turning uncertain activities into a promised date.14 November 2026 · 7 min read
Construction & ProjectEarned value management in plain English: CPI, SPI and what to do about themTurn planned value, earned value and actual cost into useful decisions without confusing budget performance with cash flow or time.14 November 2026 · 7 min readAbout the author
Dr. Hassan Khames Eliwa holds a PhD in Construction & Built Environment and has more than 20 years of international project controls experience. He is Director of Eliwa Project Controls Limited in Auckland and founder of PMMilestone.org and PMMilestone.com.
Buy me a coffee