Paint Calculator
This paint calculator estimates litres, US gallons and full cans from room dimensions or an entered wall area. It deducts doors and windows, multiplies the remaining area by coats, and divides by the paint’s stated coverage per coat.
By Dr. Hassan Khames EliwaLast updated
Result
- Net wall area
- 40.00 m²
- Paint needed (US gallons)
- 2.11 US gal
- Paint purchased
- 10.00 L
- Left after estimated use
- 2.00 L
- Paintable walls: 40 (88.9%)
- Doors and windows: 5.00 (11.1%)
How it works
Choose the measurement method
Room-dimensions mode calculates four walls from 2 × (length + width) × height. It assumes a rectangular room, uniform wall height and no ceiling. Measure wall faces rather than the floor area. A room’s floor area alone cannot establish how much wall surface it has.
Total-wall-area mode accepts a gross wall area that you measured separately. This suits corridors, multiple rooms and irregular plans. Add each wall’s length times height, including appropriate triangular sections for gables. Enter square metres in metric mode or square feet in imperial mode. The entered area should still include openings if you will deduct them using the fields below.
Deduct only what will not be painted
Door and window fields use a count multiplied by an area per opening. If the openings differ in size, enter an average area or combine them into a single equivalent opening. Counts must be whole numbers. An opening area is ignored when its count is zero, so an unused opening does not need a positive size.
The calculation rejects deductions equal to or greater than the gross area. This usually signals that openings were counted twice or measured in different units.
Use the coverage printed on the product
Metric coverage is square metres per litre; imperial coverage is square feet per US gallon. Can sizes use litres or US gallons respectively. The displayed conversion uses exactly 3.785411784 litres per US liquid gallon; an imperial UK gallon is different.
Coverage must be a per-coat figure. The coat count is applied separately in the paint-volume calculation. Halving the coverage for a two-coat job would count those coats twice. Surface texture, porosity, colour change and application method affect actual yield. No extra loss allowance or primer is included. For different products or finishes, calculate each product separately rather than pooling their volumes.
Worked example
Two coats in a rectangular bedroom
Select metric and room dimensions. Enter length 5 m, width 4 m and height 2.5 m. Gross wall area is 2 × (5 + 4) × 2.5 = 45 m².
Deduct one door of 2 m² and two windows of 1.5 m² each. The total deduction is 5 m², leaving 40.00 m² of paintable wall. For two coats at 10 m² per litre, the required quantity is 40 × 2 ÷ 10 = 8.00 L, equivalent to 2.11 US gal.
With 2.5 L cans, round 8 ÷ 2.5 upward to buy 4 cans. The purchase contains 10.00 L and leaves an estimated 2.00 L after application. That remainder is a planning estimate, not a guarantee of touch-up stock.
Expert tips
Common mistakes
- Entering floor area as wall area can severely understate the work. Measure the wall surfaces or use room-dimensions mode.
- Deducting doors and windows from a wall area that was already net removes them twice. Decide whether your measured total is gross or net before using the opening fields.
- Treating full-can surplus as an included waste allowance is risky. Some jobs produce very little surplus after rounding, so allow for expected application losses explicitly in your planning.
Frequently asked questions
Does this include the ceiling?
No. Room mode covers the four walls only. Calculate a ceiling separately using its area and the ceiling paint’s coverage, then combine purchases only if the exact same product is suitable.
Can I enter zero doors or windows?
Yes. Set the count to zero and that opening category contributes no deduction. Its area field is then ignored by the calculation.
Does it include primer?
No. Primer has its own coverage and coat requirements. Run a separate estimate using the primer label and the area that actually needs priming.
What happens when I switch units?
Existing numbers are reinterpreted in the new units; they are not automatically converted. Update dimensions, opening areas, coverage and can size together before relying on the result.
Can I use UK gallons?
Not directly. The imperial option uses US liquid gallons. Convert UK product quantities and coverage to litres first, then use metric mode to avoid mixing gallon definitions.
Related calculators
Related guides
Construction & ProjectHow to order concrete without running short or overpayingA field-focused guide to concrete quantities, thickness checks, sensible allowances and the delivery details that prevent expensive surprises.14 November 2026 · 7 min read
Construction & ProjectThree-point estimating: when PERT beats a single guessA practical guide to three-point duration estimates, weighted averages and the limits of turning uncertain activities into a promised date.14 November 2026 · 7 min readSources and standards
About the author
Dr. Hassan Khames Eliwa holds a PhD in Construction & Built Environment and has more than 20 years of international project controls experience. He is Director of Eliwa Project Controls Limited in Auckland and founder of PMMilestone.org and PMMilestone.com.
Buy me a coffee